Fluke 8060A 4 1/2 Digit Multimeter With Fluke Test Leads
Item History & Price
Reference Number: Avaluer:45991942 | Features: True RMS |
Display: Digital | MPN: 8060A |
Brand: Fluke | UPC: Does not apply |
Working Fluke 8060A multimeter in good working condition with Fluke test leads
Details:meter body has no cracks/chips but has some discoloration and engraving - see photospushbuttons all work and are in good shapedisplay segments all work with good contrastthe internal screw posts are in-tactthe RMS converter chip is socketed - I used this unit to test RMS chipsmissing two top rear rubber pads (battery holder has them)Fluke test leads have shrouded banana connectors and swa...ppable tips/alligator clipsincludes new 9v Duracell Procell battery
The following rudimentary tests were performed:Display power on self test showing all segmentsOhms measurement (600 ohm 1% resistor and shorting bar, 2.4k ohm 0.01% resistor)DC voltage (using 1vdc and 20vdc to show various ranges)AC voltage (using ~8.6vac 1 kHz source)AC frequency (using ~8.6vac, ~60 Hz source)Current test (11.09mA using 100 Ohm resistor, LED and ~3vdc)Diode check (0.5246v using power rectifier)Also checked other AC DC ranges, 2.4k & 49.995k 0.01% ohm resistors, Rel, Continuity w/ Beeper but don't have photos
The photos show various readings compared with a Fluke 87-3 series meter, labeled "test", which is not included. Let me know if there is another test you'd like me to perform. No cables or equipment used to perform tests is included unless otherwise noted.
Please view the photos and contact me if you have any questions
Details:meter body has no cracks/chips but has some discoloration and engraving - see photospushbuttons all work and are in good shapedisplay segments all work with good contrastthe internal screw posts are in-tactthe RMS converter chip is socketed - I used this unit to test RMS chipsmissing two top rear rubber pads (battery holder has them)Fluke test leads have shrouded banana connectors and swa...ppable tips/alligator clipsincludes new 9v Duracell Procell battery
The following rudimentary tests were performed:Display power on self test showing all segmentsOhms measurement (600 ohm 1% resistor and shorting bar, 2.4k ohm 0.01% resistor)DC voltage (using 1vdc and 20vdc to show various ranges)AC voltage (using ~8.6vac 1 kHz source)AC frequency (using ~8.6vac, ~60 Hz source)Current test (11.09mA using 100 Ohm resistor, LED and ~3vdc)Diode check (0.5246v using power rectifier)Also checked other AC DC ranges, 2.4k & 49.995k 0.01% ohm resistors, Rel, Continuity w/ Beeper but don't have photos
The photos show various readings compared with a Fluke 87-3 series meter, labeled "test", which is not included. Let me know if there is another test you'd like me to perform. No cables or equipment used to perform tests is included unless otherwise noted.
Please view the photos and contact me if you have any questions